Manufacturing & Quality>Reliability test results
Reliability test results
For ongoing production, reliability checks are to be conducted on a defined frequency.
The common measurement is “L10” life, defined as the number of revolutions before metal fatigue first appears on 10% of a large group of like bearings. This is referred as basic rating life of fatigue life.The relationship between the basic rating life, the basic dynamic load rating and the bearing load is given in following formula:
The common measurement is “L10” life, defined as the number of revolutions before metal fatigue first appears on 10% of a large group of like bearings. This is referred as basic rating life of fatigue life.The relationship between the basic rating life, the basic dynamic load rating and the bearing load is given in following formula:
Rolling Bearing Fatigue Life Test Report | |||||||||||
Testing Purpose And Method | To test fatigue life of deep groove ball bearing 6205 ZZ entrusted by Huanchi Bearing Group Co.,Ltd. The bearing dynamic load rating Cr=14KN. Apply pure radial load. Adopt number suspend test method. | ||||||||||
Product Type: 6205 ZZ Test Conditions | Tester Type | ABLT-1 | |||||||||
Rating Life | L10=100h | ||||||||||
Test Bearing Speed | 4000rpm | ||||||||||
Load | Radial Load | Fr= 4.85KN | |||||||||
Axial Load | Fa=0 KN | ||||||||||
Lubrication and cooling | Grease Lubrication | ||||||||||
Test Beginning Date | Test Ending Date | ||||||||||
Test Result | |||||||||||
Number | Sample No. | Test Time (h) | Failure Part (s) | Remark | |||||||
1 | 1# | 347 | INNER RING FAILURE | ||||||||
2 | 2# | 292 | OUTER RING FAILURE | ||||||||
3 | 3# | 325 | INNER RING FAILURE | ||||||||
4 | 4# | 325 | OUTER RING FAILURE | ||||||||
5 | 5# | 331 | OUTER RING FAILURE | ||||||||
6 | 6# | 360 | NO FAILURE | ||||||||
7 | 7# | 304 | INNER RING FAILURE | ||||||||
8 | 8# | 360 | NO FAILURE | ||||||||
Remark | |||||||||||
Approver | Examinant | Compiler | |||||||||
(Notice) 1. This report is invalid without “special inspection seal” and ”testing organization common seal” 2. This report is not allowed to make copies without approver's written approval. copy will be invalid without permission. 3.This report is invalid without signatures of approver,verifier and organizer. 4. This report is invalid if it is changing and incomplete. 5. Please propose your views within 15 days from the received date if you have some disagreement about it.There is no acceptance if exceed the limit time. 6. The report is responsible for the sample. |